Use your own designated
quartz beaker to prevent contaminating your wafers. If your wafers are already
gold contaminated you may use the beakers or holders at the wbgeneral (all
of them are gold contaminated). Once you use a contaminated beaker -- your
wafers must be considered contaminated and are restricted as to what equipment
they may use (see MATERIALS
)
PROCESS
Pour fresh Phosphoric Acid in your own designated quartz
beaker and cover with your own designated lid to prevent evaporation.
Heat solution to 155C.
NOTE: Wafers should not have resist on them when
going into nitride strip bath.
Use your own designated Teflon cassette for this etch
to prevent contamination.
Dip wafers in your own designated beaker of DI water
for 15 second.
Immerse in 6:1 Buffered HF (in your own designated plastic
or Teflon beaker) for 30 seconds. This is to remove any oxide layer that is
on the top of the nitride.
Overflow rinse (in your own designated beaker) for 5
minutes.
Blow Dry.
Inspect.
Immerse the wafers in DI water for 15 seconds (in your
own designated beaker).
Immerse the wafers in the hot Phosphoric (nitride strip)
solution and replace the lid to prevent evaporation which effects the etch
rates. Note 800A of standard nitride takes about 40 minutes to strip in fresh
solution (you may want to go 50 minutes to make sure it is all off.
Overflow Rinse with DI water for 5 minutes.
Blow Dry.
Inspect to be sure all the nitride has been removed
(i.e. measure oxide under the nitride -- if it is less than or equal to what
you had originally, the nitride is off.